| Line 1: |
Line 1: |
| This folder is used by two services, which operate in a clinic with multiple instances, e.g. one for each device: | | This folder is used by two services, which operate in a clinic with multiple instances, e.g. one for each device: |
|
| |
|
| * '''Device Data Upload Service''' - This service is retrieving information from devices and writes or copies them in a device specific format to the device integration folder. The filename has this format {GIDOfDevice} | | * '''Device Data Upload Agents''' - This service is retrieving information from devices and writes or copies them in a device specific format to the device integration folder. The filename has this format {GIDOfDevice} |
| * '''KORDEUS Device Integration (KDI)''' '''Service''' - This service will load the file and trigger the internally availbale data converter for the device identified by the GID of the device | | * [[KORDEUS Device Integration (KDI) Agent]] - This service will load the file and trigger the internally availbale data converter for the device identified by the GID of the device |
| | |
| === ToDo ===
| |
| | |
| * Device Data Upload Server should take the information and write it to an envelope in a standard format defining from which device-instance the information it is coming from. This file is put into the <code>/input</code> folder
| |
| * The KDI will read the envelope, will detect the device-type (e.g. IOL Master 700) of device-group-type (e.g. optical biometer). This information is managed with KORDEUS admin tools.
| |
| * With this device type KDI will invoke the device-type specific data parser centrally and convert the information into a standard format. Once the conversion was successful:
| |
| ** KDI writes the converted files to a <code>/convertedOK</code> folder, which holds all information in a standard import format, which still holds the original file information presented by the device in a binary format.
| |
| ** If KDI does not succeed, it will move the failed conversion file to a <code>/conversionFailed</code> folder
| |
| * Upon request the data can be imported into the database. Before the data is used, the standard import format is saved to the DMS and receives a documentID there, which is kept with the dataset
| |
| * KDI will archive all files to the document-management system.
| |
| ** from the <code>/input</code> folder before deleting them physically from the hdd
| |
| ** from the <code>/convertedOK</code> folder, after it has been imported once
| |
| | |
| Goal
| |
| | |
| * Each Device Data Upload Service, has a setting file, which holds the device-type and deviceID, which was created earlier with KORDEUS admin tools
| |
| * Once any of the device data is used, it can be tracked in the DMS-System (so if a device error happens, we can prove that later).
| |
|
| |
|
|
| |
|
This folder is used by two services, which operate in a clinic with multiple instances, e.g. one for each device:
- Device Data Upload Agents - This service is retrieving information from devices and writes or copies them in a device specific format to the device integration folder. The filename has this format {GIDOfDevice}
- KORDEUS Device Integration (KDI) Agent - This service will load the file and trigger the internally availbale data converter for the device identified by the GID of the device
See also